How To Install the Favorite Vent Used by The Cannabis Grower in a Shipping Container

In this video, follow along as Channing & Will show you how to install a powered vent on your shipping container! Vents are necessary in simple storage containers or container homes.

Installing the AC Infinity T10 Exhaust Vent in a Shipping Container

Channing McCorriston, The Container Guy, walks through the installation of the AC Infinity T10 exhaust vent inside a shipping container and explains why this system is one of the best ventilation solutions available for non insulated containers.

This setup combines high airflow performance with smart environmental control, making it ideal for storage containers, modified builds, and specialty environments.


Why Ventilation Matters in Containers

Non insulated shipping containers trap heat and moisture quickly. Internal temperature and humidity often differ significantly from outside conditions.

Proper ventilation:

  • Reduces condensation

  • Controls humidity

  • Regulates temperature

  • Protects stored contents

  • Prevents mold and corrosion

The AC Infinity system provides both airflow and intelligent monitoring.


AC Infinity T10 Fan Specifications

The preferred model for containers is the 10 inch T10.

Key details:

  • 631 CFM airflow

  • DC powered motor

  • Highly energy efficient

  • Fits within standard 11 inch corrugations

  • Exchanges air inside a 20 foot container approximately every 2 minutes

Available sizes include:

  • 10 inch

  • 12 inch

  • 14 inch

  • 16 inch

The 10 inch version fits container corrugations with minimal modification, making it the most practical option.


Balanced Airflow Setup

Proper airflow requires pairing the exhaust fan with intake dampers.

Recommended ratio:

  • Two 10 inch intake dampers

  • One 10 inch exhaust fan

This creates balanced air exchange and prevents negative pressure issues.


Smart Controllers and Monitoring

AC Infinity controllers offer:

  • Continuous temperature monitoring

  • Continuous humidity monitoring

  • Data logging

  • Bluetooth connectivity

  • Wi Fi capability in newer models

  • Threshold automation for high and low set points

Users can program the system to automatically activate when environmental limits are exceeded.

The result is automated container climate control.


Dedicated T10 Container Frame

Container Modification World developed a dedicated split frame specifically for the T10.

Frame features include:

  • Exterior drip edges to prevent water intrusion

  • Interior M6 riv nuts for mounting

  • Interior flanges for steel stud framing

  • Insulation ready design

  • Half inside and half outside mounting system

The frame improves weather resistance and simplifies installation.


Installation Overview

Basic installation steps:

  1. Slide interior frame through the container wall

  2. Secure with rivets

  3. Install remaining rivets after fan positioning

  4. Attach steel stud brackets to interior flanges

  5. Mount fan to interior riv nuts

  6. Install intake dampers

  7. Mount controller

Controllers can be magnet mounted or secured with self tapping screws to prevent movement during transport.


Power Supply Solutions

Containers often lack built in electrical wiring.

Avoid running power through door seals.

Recommended solution:

  • Drill a 2 inch hole

  • Install a weatherproof exterior receptacle or dongle

  • Plug extension cord from outside

  • Power system internally cleanly and safely

This maintains weather resistance and avoids damaging door seals.


Sensor Placement

The included temperature and humidity sensor should be:

  • Positioned centrally inside the container

  • Routed cleanly along structural members

  • Protected from direct airflow for accurate readings


Placement Warning

Avoid installing vents within the first four feet of container doors.

Reasons:

  • Door handles may collide with rain guards

  • Door swings may damage the vent

  • Lock rod interference

If installed near doors, protective measures must be added.

Planning vent placement early prevents these issues.


Final Assessment from The Container Guy

The AC Infinity T10 system offers:

  • High airflow efficiency

  • Intelligent environmental control

  • Clean integration with container framing

  • Reliable moisture management

  • Professional installation finish

When paired with a dedicated container frame and proper intake dampers, this system becomes one of the most effective container ventilation solutions available.


Quick Feature Summary

Feature AC Infinity T10
Airflow 631 CFM
Motor Type DC
Air Exchange Every 2 minutes in 20 ft container
Control Options Bluetooth and Wi Fi
Monitoring Temperature and humidity logging
Recommended Setup 2 intake dampers per 1 exhaust
Frame Split interior exterior with drip edges
Installation Tip Keep 4 feet clear from doors